MikeHoltNEC
MikeHoltNEC
  • 271
  • 7 263 172
I'm really bummed out that I can't post a technical NEC Video today, I'm on vacation, be safe.
I'm really bummed out that I can't post a technical NEC Video today; I'm on vacation . So I'm sharing my run on a double black jump line (Candyland) Angle Fire Bike park at the silly age of 73.
Переглядів: 757

Відео

GFCI Protection of Outdoor Outlets , NEC 2023 - [210.8(F)], (1min:47sec)
Переглядів 2 тис.15 годин тому
With each new edition of the National Electrical Code, more locations require GFCI protection, but what if GFCI protection creates more of a nuisance than a benefit? Such might be the case when it comes to GFCI protection of certain outdoor outlets as required by NEC section 210.8(F). Learn how the NEC considered such outdoor outlets by watching this brief video where Mike and the team explain ...
What is a young gun?
Переглядів 61714 днів тому
What is a young gun?
Anti Short Bushing for MC Cable
Переглядів 4,5 тис.21 день тому
Anti Short Bushing for MC Cable
Use the correct grounding terminal bar [440.40].
Переглядів 2,7 тис.21 день тому
Use the correct grounding terminal bar [440.40].
Why some people become Dinosaurs, and how you can prevent this from happening to you!
Переглядів 3,7 тис.28 днів тому
Why some people become Dinosaurs, and how you can prevent this from happening to you!
Raceway above the level of uninsulated live parts shall use fittings listed for wet location, 312.2.
Переглядів 4,7 тис.Місяць тому
Raceway above the level of uninsulated live parts shall use fittings listed for wet location, 312.2.
Identification of Disconnecting Means, 2023 NEC [110.22], (15min:05sec)
Переглядів 3,8 тис.Місяць тому
Identification of Disconnecting Means, 2023 NEC [110.22], (15min:05sec)
Bonding bushing/jumpers are not required for raceways that enter a clean punch KO. See NEC 250.97
Переглядів 2,7 тис.Місяць тому
Bonding bushing/jumpers are not required for raceways that enter a clean punch KO. See NEC 250.97
Clearly many in the industry have no clue that an inspector cannot make up their own rules. See 90.4
Переглядів 6 тис.Місяць тому
Clearly many in the industry have no clue that an inspector cannot make up their own rules. See 90.4
Generac generator power/control wires can be in the same raceway [NEC 110.3(B) and 300.3(C)(1)].
Переглядів 1,9 тис.Місяць тому
Generac generator power/control wires can be in the same raceway [NEC 110.3(B) and 300.3(C)(1)].
Are insulating bushing required for Liquidtight Flexible Nonmetallic Conduit (LFNC) fittings?
Переглядів 2,3 тис.Місяць тому
Are insulating bushing required for Liquidtight Flexible Nonmetallic Conduit (LFNC) fittings?
Burying electrical wiring, Mike@MikeHolt.com
Переглядів 1,1 тис.Місяць тому
Burying electrical wiring, Mike@MikeHolt.com
What is an AHJ?
Переглядів 363Місяць тому
What is an AHJ?
Using the Formula Wheel
Переглядів 3,1 тис.2 місяці тому
Using the Formula Wheel
The grounding electrode conductor is permitted to originate at the meter enclosure, 250.24(A)(1).
Переглядів 4,9 тис.2 місяці тому
The grounding electrode conductor is permitted to originate at the meter enclosure, 250.24(A)(1).
Electric Vehicle Power Transfer System, NEC 2023 - [Article 625], (16min:00sec)
Переглядів 4,3 тис.3 місяці тому
Electric Vehicle Power Transfer System, NEC 2023 - [Article 625], (16min:00sec)
Special Occupancies Scope [500.1], NEC 2023, (3min:11sec)
Переглядів 2,5 тис.4 місяці тому
Special Occupancies Scope [500.1], NEC 2023, (3min:11sec)
Three fantasies related to ground rods at metal light poles. MikeHolt.com/Fantasies
Переглядів 6 тис.4 місяці тому
Three fantasies related to ground rods at metal light poles. MikeHolt.com/Fantasies
Mike Holt Apprenticeship - A Training Director's Perspective...
Переглядів 6324 місяці тому
Mike Holt Apprenticeship - A Training Director's Perspective...
How Surge Protective Devices Function
Переглядів 9 тис.4 місяці тому
How Surge Protective Devices Function
Auxiliary Grounding Electrodes [250.54], NEC 2023, (10min:54sec)
Переглядів 6 тис.5 місяців тому
Auxiliary Grounding Electrodes [250.54], NEC 2023, (10min:54sec)
Dangers of Multiwire Circuits 28.6
Переглядів 7 тис.5 місяців тому
Dangers of Multiwire Circuits 28.6
Surge Protective Devices
Переглядів 2,6 тис.5 місяців тому
Surge Protective Devices
Suitable Wiring Methods [110.8], 2023 NEC, (6min:45sec)
Переглядів 10 тис.6 місяців тому
Suitable Wiring Methods [110.8], 2023 NEC, (6min:45sec)
AFCIs, Clearing Series and Parallel Arcing Fault
Переглядів 6 тис.6 місяців тому
AFCIs, Clearing Series and Parallel Arcing Fault
Servicing and Maintenance of Equipment [110.17], 2023 NEC, (06min:53sec)
Переглядів 4,5 тис.7 місяців тому
Servicing and Maintenance of Equipment [110.17], 2023 NEC, (06min:53sec)
An Instructor's Thoughts on Mike Holt Apprenticeship Curriculum
Переглядів 9007 місяців тому
An Instructor's Thoughts on Mike Holt Apprenticeship Curriculum
Ground-Fault Protection of Equipment
Переглядів 3,8 тис.7 місяців тому
Ground-Fault Protection of Equipment
Raceways Exposed to Different Temperatures [300.7, 2020 NEC]
Переглядів 3,6 тис.8 місяців тому
Raceways Exposed to Different Temperatures [300.7, 2020 NEC]

КОМЕНТАРІ

  • @MrI8igmac
    @MrI8igmac 16 годин тому

    Does the new nec say only one neutral per terminal screw?

    • @MikeHoltNEC
      @MikeHoltNEC 15 годин тому

      See 408.41. Answer: Yes

    • @MrI8igmac
      @MrI8igmac 15 годин тому

      @MikeHoltNEC recently in class this was discussed, but i was not sure if it was both ground and neutral. I have seen 12awg and 14awg sharing a terminal screw. Preventing 14awg from a solid connection.

    • @MikeHoltNEC
      @MikeHoltNEC 11 годин тому

      Only one neutral permitted under a terminal, see 408.41. When a terminal is 'identified' for two wires, we need to read the instructions on the wire sizes [110.3(B)]. In Square D breakers for 15-20A, both wires must be the same size.

  • @simplewick350
    @simplewick350 17 годин тому

    So for a whole home Generac with a 100 amp breaker in the Generac unit, would you size the feeder off table 310.12, since the feeder is supplying the entire load of the home when power is lost.?

    • @MikeHoltNEC
      @MikeHoltNEC 16 годин тому

      I do not know, but it's not a good idea.

  • @rikmehin4159
    @rikmehin4159 18 годин тому

    I will be installing a 75 kva 3 phase s/u xfmr, 240 hi-leg primary to 480/277 secondary. it will supply power for a glycol chiller located 60 feet from xfmr equip. Do I need both pri and sec protection and what size fuses and wire?

    • @MikeHoltNEC
      @MikeHoltNEC 16 годин тому

      Please get my transformer app at MikeHolt.com/App

  • @333mikeray
    @333mikeray 18 годин тому

    Its the Power Company that is actually laying down ultimate and over NEC codebook to date. Gotta use 4 Awg solid copper from every outside disconnect to the 2 ground rods for meter change outs and UFER for new builds with access to connector. Wanna argue here's an 800 number well get back to you next month after you argue your case with call center in India. I tell them just change the damn ground wire with #4 AWG from HD $37 and rehook the electric meter.

  • @SRCardow1
    @SRCardow1 18 годин тому

    Watch out for those trees!😮😮

  • @SRCardow1
    @SRCardow1 18 годин тому

    You'll be fine.😅

  • @333mikeray
    @333mikeray 18 годин тому

    You be carful sir ! The mountain bike injury at 50 yo is what started my downfall.

  • @ammaraldulaimi3237
    @ammaraldulaimi3237 19 годин тому

    Mike this is the best application for life and work balance code.

    • @MikeHoltNEC
      @MikeHoltNEC 16 годин тому

      Call 352.360.2620 I have a book/video on this topic.

  • @poolsdoc9178
    @poolsdoc9178 22 години тому

    Awesome!👏

  • @stevenholquin2127
    @stevenholquin2127 22 години тому

    This is Outstanding I Like This Video This Video Is Super Helpful And Correct and Recite From The NEC National Code Book 📖 Ladies and Gentlemen It’s Important To Understand Just How To Read The NEC National Code Book First If The Book Says You Shall That Means You Will Remember The National Code Book is in a Matter of Fact Language There is To Maybe No Might Be No Could Be It’s All in a Matter of Fact Language This is Important You Read The Book As a Matter of Fact This is Why You See The IBEW Logo It’s a Right Fist With a Suit Shirt Jacket And Cufflink….This Represents That Electrical Workers Are Not Blue Collar Workers We Use Our Brains 🧠 Not Our Backs

  • @xXBuckOFiveXx
    @xXBuckOFiveXx День тому

    Awesome to see you having fun Mike! Thank you for all you do for the industry!

  • @OneMillionBuddhas
    @OneMillionBuddhas День тому

    Looks intense!

  • @kylecanning9216
    @kylecanning9216 День тому

    Is the tablet just sitting on the bus bar? 🤣

  • @kylecanning9216
    @kylecanning9216 День тому

    I dont think the double barrel mc connectors with the screw in the middle have a stopper. I think they are arlington?

  • @9111logic
    @9111logic День тому

    Wow ! ! That is some going Mike !

  • @jbecker386
    @jbecker386 День тому

    That's impressive Mike!

  • @user-zw4mk6qu8b
    @user-zw4mk6qu8b День тому

    Wow that’s amazing how you drive that bike.👏

  • @kevin_ppk
    @kevin_ppk День тому

    In this day and age, iti s common sense to implement more, we as society as progressed a lot, as for as technologies goes, so why the heck would these manufacturers or company still making standard breakers or devices that only support 1 wire

  • @aurorian1634
    @aurorian1634 День тому

    Even though it wasn't live, that was still a nail-biter show. 😮

  • @josephdiaz878
    @josephdiaz878 День тому

    thank you

  • @travishamilton1659
    @travishamilton1659 День тому

    Wooowwwww👀👏👏👏👏🚴 Can't believe you got that much air time. That is awesome.😀 Go ahead Mike with your bad self

  • @jt2112able
    @jt2112able День тому

    Impressive, Mike!!!

  • @dkline8874
    @dkline8874 День тому

    That’s some crazy riding Mike, keep having fun.

  • @Justin-jf4ub
    @Justin-jf4ub 2 дні тому

    Love it

  • @JoseRivera-fv7cc
    @JoseRivera-fv7cc 2 дні тому

    Wow. My respect Mike. God Bless You

  • @Flipd_TV
    @Flipd_TV 2 дні тому

    Awesome video !!

  • @rafalszachnowicz2831
    @rafalszachnowicz2831 2 дні тому

    Have fun, sir! When I retire, I wanna fallow the same path.

  • @lashlyismail1070
    @lashlyismail1070 2 дні тому

    Great job

  • @frankdagreat598
    @frankdagreat598 2 дні тому

    That was crazy..

  • @Floyd..B
    @Floyd..B 2 дні тому

    So great Mike ! Enjoy your vacation.

  • @Tsykal
    @Tsykal 2 дні тому

    Also, the HVAC equipment is hardwired (no plug/outlet)

  • @robertmartin5167
    @robertmartin5167 2 дні тому

    Mike . How can I use it to size for a disconnect.?

  • @robertmartin5167
    @robertmartin5167 2 дні тому

    It is the best app for me

  • @jeromeherring3989
    @jeromeherring3989 2 дні тому

    I would love to take your course and get my license after 27 years of residential electrical

    • @MikeHoltNEC
      @MikeHoltNEC День тому

      You can do it! Call 352.360.2620

  • @JpSnareGuy
    @JpSnareGuy 2 дні тому

    Good day. Would residental lift stations also require GFCI protection? Cord connected? Hard wired with a disconnect? My interpretation would say yes regardless. Thank you.

  • @kangaroogod
    @kangaroogod 2 дні тому

    👍🏽

  • @Davidgraney
    @Davidgraney 2 дні тому

    Only one

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      Please watch the video again and the NEC rule so you'll understand why your comment doesn't make you look good...

    • @Davidgraney
      @Davidgraney 2 дні тому

      @@MikeHoltNEC don't care

    • @MikeHoltNEC
      @MikeHoltNEC День тому

      There are no products suitable for (2) or (3) so it's a moot point.

  • @Christiones
    @Christiones 2 дні тому

    Mike you’re a living legend. Thank you for everything.

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      Just an electrician that wants to help others in the industry.

  • @agmhelena7266
    @agmhelena7266 2 дні тому

    damn, people just claim it's not up to code without reading the code?

  • @jamesbsa6450
    @jamesbsa6450 2 дні тому

    My interpretation, would include oudoor pool pumps less than 50A, water pumps, etc.

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      👍

    • @duffmeister6480
      @duffmeister6480 2 дні тому

      Only if the pool pumps are 110V, most are 220V ?

    • @MikeHoltNEC
      @MikeHoltNEC День тому

      210.8(F) applies to 120V, 240V, and 120?240V circuits. The 150V to ground means any circuit where the voltage to ground does not exceed 150V.

    • @duffmeister6480
      @duffmeister6480 День тому

      @@MikeHoltNEC it’s been a long time, retired 13 years, I like your channel, like to keep somewhat abreast of the industry. Thanks.

    • @MikeHoltNEC
      @MikeHoltNEC День тому

      💕

  • @vince6829
    @vince6829 2 дні тому

    Thank you for sharing your knowledge

  • @luislazogue8089
    @luislazogue8089 2 дні тому

    Hey Mike, what about pool heaters?

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      Nope, per the exception to 210.8(F).

  • @nycoastie
    @nycoastie 2 дні тому

    You’re awesome! Thanks, Mike

  • @Rakhesh30MN
    @Rakhesh30MN 2 дні тому

    Hello Mike please do the video on Generator set and it's temporary earthing cable size

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      None required for systems under 1000V.

  • @JennellStraughter
    @JennellStraughter 2 дні тому

    Ho guardato questo video al lavoro e ora anche i miei colleghi stanno ridendo. Un ottimo modo per risollevare l'umore in ufficio🍭

  • @sokbok
    @sokbok 2 дні тому

    B. Brooks very patient with Mike Holt here.

  • @michaelnoble2432
    @michaelnoble2432 2 дні тому

    Using aluminum conductors for domestic wiring is just BONKERS.

  • @saw288
    @saw288 3 дні тому

    My favorite MH video

  • @UKsystems
    @UKsystems 3 дні тому

    You need more than shall be so identified. You also need to validate with the manufacturer directly themselves. What means more than one wire can be put in.

  • @kjward1975
    @kjward1975 3 дні тому

    Mike can u run Romex in Conduit

    • @MikeHoltNEC
      @MikeHoltNEC 2 дні тому

      Yep, see 358.22, but not if outside, see 300.9 and 334.10(B)(4).

    • @kjward1975
      @kjward1975 2 дні тому

      @@MikeHoltNEC thanks buddy

    • @MikeHoltNEC
      @MikeHoltNEC День тому

      👍